AT&T Release 2.0 Telephone User Manual


 
Unit Load Calculation Worksheet
Qty x Unit Load
= Total
Equipment
Hybrid/PBX
or Modified
Square
Optional Equipment †
Direct Station Selector ‡
General Purpose Adapter
Hands-Free Unit
Headset Adapter
0.7
0.8
0.8
0.8
0.9
1.0
1.0
1.0
Total Actual Unit Load
The MFM has its own wall power unit located at the telephone and therefore is
not added to the unit load calculation.
Up to two DSSs (one DSS per MLX-28D or MLX-20L console) can be powered
from each control unit carrier. For example, a three-carrier system can have six
system operator positions, each with one DSS powered from the control unit.
If the total actual unit load is less than or equal to 54, auxiliary power is
not required.
If the total actual unit load is greater than 54, continue to Step 7.
Unit Load Worksheet B-5