Unit Load Calculation Worksheet
7. Try to exchange modules between carriers to reduce the unit loads to 54.
(Remember that the 100D, 400, 400 GS/LS/TTR, 800, and 800 GS/LS modules
have unit loads of 0.0.) Repeat Steps 1 through 6 to recalculate unit loads for
the new configuration.
■ If the exchange reduces the unit load to 54 or less, auxiliary power is
not required.
■ If the exchange does not reduce the unit load to 54 or less, auxiliary
power is required. Continue to Step 8.
NOTE:
Empty slots are not permitted between modules.
B-6 Unit Load Worksheet