Toshiba DK96 Telephone User Manual


 
REMOTE AOMIN & MAINT PROCEDURES
SECTION 200-096-600
FEBRUARY 1991
TABLE RM-BD
MODE 95
REMOTE CALLING STATION MESSAGING (ADD/REVIEW/CHANGE) .
iTEP
ACTION
DISPLAY/PRINTOUT
1
Enter the Message Mode
>MODE MESG
At the >MODE prompt, enter m 0 1 a
q
.
2
To Add Or Review a Calling Station Message
m 95
Set the terminal keyboard to the lower case (cap lock off) and
enter QII.
NOTE:
Enter “m” anytime it is desired to start over in this procedure.
3
Enter 1 1 1 (XXX = station number where the message will be
m95 XXX
set and stored).
4
Enter B [7(7 (p = page command and
m95 xxx ~017
[Ml
00 = 2-digit message memory location: IO - 19 personal
messages and 60 = 99 = system message).
NOTES:
1. To store system messages permanently, EKT XXX must be the
station at port 00.
2. After 1 00
IS entered, the previously stored message is
displayed. If there is no stored message, nothing is displayed.
5
To Change Previous Message
m95 xxx ~00
W+l
Set the terminal keyboard to upper case and change message
(alphanumeric, 32 characters max.).
6
To Set the Message on EKT XXX’s LCD
Set the terminal keyboard to lower case and enter BmI .
m95 XXX
p mo[M+] p
m0
-L Zero
7 To Exit the Message Mode
m0
At any time, enter 111 (lower case).
9
> MODE
NOTES:
I. To cancel a message set via Mode 95, use Mode 97 procedure.
2. [M] represents the message entered.
3. With
Release 2
software only, remote calling station messaging is not available from electronic
telephones, but it is available from ASCII terminals connected to the TTYport or via IMDU on the
PIOU
or
PIOUS.
-52-