Toshiba DK96 Telephone User Manual


 
PROGRAMMINGPROCEDURES-INSTRUCTIONWSYSTEMRECORDS
SECTION 200-096-302
FEBRUARY1991
PEPU can be assigned to operate with the
Door Lock function or with External Page
for mute control. The door lock button is
assigned in
Program 39;
the door lock
activation time is assigned in
Program
77-1.
This door lock function is not associ-
ated with the HDCB door lock; it is an
addition to HDCB door locks.
l
NT Relay, LED
06-A relay, located on the
PIOU, PIOUS or PEPU, can be assigned to
operate in one of two Night Transfer modes
(see next item, MOH/NT Relay). In one
mode, the relay will activate for 1 second,
and then be idle for 3 seconds when a CO
line rings (incoming), and the system is in
the night mode. The intended application is
to control an external ringing device at
night.
Program 78
must have Ring Over
External Page activated for this feature. In
the second mode, the relay will operate
continuously after Night Transfer (m
m) has been activated. One application
is for control of an external answering
machine.
l
MOH/NT Relay, LED
05-A relay, located
on the PIOU, PIOUS or PEPU, can be
assigned to operate in one of two applica-
tions. A choice must be made between use
for Night Transfer application (see NT Relay
above) or Music-on-Hold (MOH). If used
for MOH, the relay will activate when any
CO line or station is placed on hold. The
intended application is to control a tape
player which is used as a Music-on-Hold
source.
called door phone does not exist. Door
phones 1 A, 1 B, 1 C are numbered 151, ..
-3,
152, 153, respectively, and are connected .”
to the HDCB at port 04. Door phones 2A,
2B, 2C are numbered 154, 155, 156, re-
spectively, and are connected to the HDCB
at port 12, etc.
l
Each HDCB B-jack output can be config-
ured as a door lock control. Door lock
control buttons for HDCB door locks are
assigned to electronic or digital telephones
in
Program
39. Door lock activation time is
1
set in
Program 77-l.
A maximum of four
HDCB door lock controls are available with
a PCTU PCB; three are provided with a
PCTUS PCB. Each HDCB requires one
PEKU or PESU electronic telephone port.
These door locks are not associated with,
but are in addition to, the door lock
provided by the PIOU, PIOUS, or
PEPU PCBs. HDCB door lock control is
available with
Release
2 and above soft-
ware only.
Program 78-CO Line Special Ringing Assign-
ments:
l
Ring Over External Page During Night
Mode, Feature
I-This program selects
which CO lines will activate ringing over
external paging facilities during the NT1 or
NT2 modes. The NT Relay will also be
activated if it is in the l-second on/
3-seconds off mode.
Program 77-2-Door Phone and Door Lock
Busy Assignments:
l
Each door phone controller (HDCB) can
interface with up to three door phones. The
system treats each HDCB as a station.
Therefore, this is quite different from all
other station arrangements using electronic
telephones or standard telephone devices.
The system does not automatically know
how many door phones are connected to
each HDCB, so it must be told. This pro-
gram is used to enter that information so
that a caller will receive fast busy tone if the
l
DISA/DISC CO Line Assignment, Fea-
ture
2-This program assigns CO lines to
be used with the Direct Inward Station
Calling (DISC) and the Direct Inward Sys-
tem Access (DISA)features
(Release2and
above). These CO lines may be set for
DISCDISA operation during the different
system modes of DAY, DAY2 and NIGHT.
A CO line will switch to normal ringing after
ten seconds if the outside caller does not
use the DISA/DISC feature. Normal
function of these lines occurs for outgoing
calls. DISA, which allows outgoing CO line
access and internal station calling, is
available with
Rel6ase
2 and above soft-
‘-
ware only.
2-18