PROGRAMMINGPROCEDURES-INTRODUCTION
SECTION 200-096-301
FEBRUARY1991
TABLEl-A
SIMPLEPROGRAM: PROGRAM33
(STATION HUNTING)
I
Press...
Step
m + LED keys
#’
Action description LCD RESPONSE . . .
1. Use the programming LCD electronic or digital telephone
NO. 205
connected to port 05 - circuit 6. JAN 20 SUN
06:43
Make sure the programming button strip template is
installed on the programming telephone (see
Paragraph 3.24).
2.
HmlEBE~
Enter programming mode.
3. mII=
PROGRAM MODE
Access Program 33. System beeps after m key
PROGRAM = 33
is pressed to indicate program number may be entered.
DATA STORE
4. m
Prepare the system for a station port selection.
5. 111 -II!
33 SELECT =
Select the port number of the Hunt From station. A
33 SELECT = (00 - 95)
range of ports can be entered as specified in on the
HUNT TO =
record sheet. After the Hunt From ports are entered,
press the fl button.
Enter the port number of the Hunt To point, as recorded
33 SELECT = (00 - 95)
on the system record sheet. Press LED key 01 to delete
HUNT TO = (00 - 95)
a digit from Hunt To point ports.
7. m
Secure data in system programming.
8. m
Prepare system for another selection (go back to
step 5), or exit Program 33 (continue with step 9).
9. [I=
Secure Program 33 data in system memory.
0. m
Exit Program 33. Enter another program number or
exit programming mode (go to step 11).
Speaker beeps to indicate it is exiting Program 33.
33 SELECT = (00 - 95)
DATA PROGRAMMED
33 SELECT =
33 SELECT = ##
DATA PROGRAMMED
PROGRAM =
1. [Bm
NO. 205
Exit programming mode.
JAN 20 SUN
06:58
I
1-3