STRATA DK
GENERAL DESCRIPTION
DECEMBER 1990
TABLE G
SYSTEM TONES -.
Idle
Ring tone 1 5001640 Hz, modulated by 16 Hz, 1 sec. ON-3 sec. OFF
electronic
telephones
Ring tone 2 600/800 Hz, modulated by 16 Hz, 1 sec. ON-3 sec. OFF
Ring transfer
540/760 Hz, modulated by 16 Hz, 1 sec. ON-3 sec. OFF
co
Line
Busy station (camp-on) 2400 Hz, modulated by IO Hz, 1 sec. ON-3 sec. OFF
Standard telephone or
VOiCf? mail port: 20
Hz,
Normal ring option:
1 sec. ON-3 sec. OFF
Distinctive ring option
(standard telephone):
0.4 sec. ON-O.2 sec.
OFF-O.4 sec. ON-3 sec. OFF
TIE line
400
Hz, 0.25 sec. ON-O.25 sec. OFF
or DISA
To busy station
or
line calls
400
Hz, 0.25 sec. ON-O.25 sec. OFF
(programmable option’)
Tone first (EKT ring signal)
500
Hz, 1 sec. ON-3 sec. OFF
Door
A&C 870 Hz, 1 sec.1710 HZ, 2-0.5 sec. (5 rings)
phone
B 870 Hz, 0.5 sec./71 0 HZ, 2-0.5 sec. (5 rings)
Busy override/DND override
2400
Hz, 1 sec. ON-3 sec. OFF
Dial (intercom)
400 Hz, continuous
Ringback
400
Hz, 1 sec. ON-3 sec. OFF
Intercom
Line
Busy
400
Hz, 0.25 sec. ON-O.25 sec. OFF
Calls
Do not disturb
400
Hz, 0.125 sec. ON-O.125 sec. OFF
Voice page warning 500 Hz, 1 sec. ON (via electronic telephone speaker)
OCA warning 500 Hz, 1 sec. ON only (via electronic telephone speaker)
Executive/privacy override warning 500 Hz, 1 sec. ON only (via handset or speaker)
Hold recall
2400 Hz, modulated by 10 Hz, 1 sec. ON-l sec. OFF
Standard telephone ringing
20
Hz, 1 sec. ON-3 sec. OFF
Voice Answer: DTMF “A”
Mail
Special
Disconnect: DTMF “D”
80/l 60 msec., dual-tone
Tones
Recall: DTMF “B”
Verified account code ‘Ode valid
400
Hz, 0.5 sec. ON
Special
Zonfirma-
confirmation tones2
Code not valid 400 Hz, 0.125 sec. ON-O.1 25 sec. OFF-O.125 sec. ON
[ion
rones
Station option programming
confirmation tones (call forward,
400
Hz, 1 sec. ON
timed reminders, etc.)
NOTES:
1. Requires
Release 3
software.
2.
Tones are sent only to the station
that enters the not to the
outside party.