Toshiba DK96 Telephone User Manual


 
REMOTE ADMIN & MAINT PROCEDURES
SECTION 200-096-600
FEBRUARY 1991
TABLE RM-BH
STATION/CO LINE STATUS CHECK
.
iTEP
ACTION
DISPLAY/PRINTOUT
1
Enter the Test Mode
>MODE TEST
At the >MODE prompt, enter 0 1 1 0
q
.
2
To Check Station Line Status
T SEKT XX IDLE ON-HOOK
Enter B 0 1 1 1 1 B I= port number. T
Possible status: Idle on-hook, idle off-hook, busy on-hook,
busy off-hook.
IMPORTANT!
To prevent service interference, station line status must be
idle on-hook before initiating a test from that station.
3
To Check CO Line Status
T SCOYY - BUSY
Enter 1 B m 1 13 1 I= CO line number.
T
Possible status: Idle, busy.
4
To Exit the Test Mode
T QUIT
At the T prompt, enter H 1 0 1
q
. > MODE
TABLE RM-BI
GENERAL STATION ACCESS AND BUTTON ACTIVATION
iTEP
ACTION
DISPLAY/PRINTOUT
1
Enter the Test Mode
>MODE TEST
At the >MODE prompt, enter 0 1 1 fi
q
.
T
2
T TKXX KYY
T
XX = Port number and YY = key number.
NOTE: Key numbers begin at 01.
3
To Activate A Function Key
TTKXXF
Enter 1 1 1 a a
D F = function key designator
4
T
pSPKR1 S
HOLD ( H
CONF C
F = S, H, C, M
MIC M
4
To Access A CO Line (via CO Access Code) and Dial Out
Enteri~~~[3~~~~~ 0~~~~~0 q .
TT=X K01 -onnn[7tlo
T
AAA = 1, 2, or 3-digit CO line access code and
0 = telephone number.
To Access A CO Line (via CO Line Key and Dial Out
5 Enter~~~~~~~ nn~~nfl~b-
YY = CO line number.
Telephone Number
6
To Exit the Test Mode
At T prompt, enter m B 0 0
q
.
,
-56-