AT&T feature module 2 Telephone Accessories User Manual


 
To answer a call:
1 Touch On/Quiet on the headset adapter.
To mute the microphone:
1 Hold down On/Quiet on the headset adapter.
To hang up:
1 Touch Off on the headset adapter.
The green light next to On/Quiet goes off.
In-Range, Out-of-Building Voice Termianl and Protectors
DESCRIPTION You can place a voice terminal in another location, outside of the main
building, but within 1000 feet of the MERLIN 11 system control unit. In order
to protect both this In-Range, Out-of-Building (IROB) voice terminal and the
control unit from exposure to lightning, contact with power lines, or power
currents induced by nearby power lines, you must also install two Model TII
341 IROB protectors.
See the example in Figure 2-24. Install one of the IROB
protectors where the cable from the control unit leaves the building, and the
other where the cable enters the building in which the IROB voice terminal
is located.
CONSIDERATIONS
FIGURE 2-24 Basic IROB voice terminal and protector configuration.
IROB
IROB
protector
protector
Interbuilding
wiring
I
-----
Approved ground
These protectors must be mounted indoors,
An approved electrical ground, such as a ground installed by the power
service company, grounded building steel, or concrete-encased ground,
is required for proper operation of the IROB protector. (For more
information about approved ground, see the instructions that come with
your IROB protectors.)
2-182 MERLIN II System Features