Nortel Networks 1000E Telephone User Manual


 
Page 82 of 466 Rack-mounting the components
NN43041-310 Standard 01.11 October 2008
Note: In the 5u pattern, a “u” is equal to 1.75 in. and includes three holes
spaced at 5/8 in. + 5/8 in. + 1/2 in.
Other data communications equipment can be installed in a rack with
CS 1000E system components.
This chapter contains the following procedures:
Procedure 1: "Removing the cover" on page 84
Procedure 2: "Rack-mounting a Media Gateway or Media Gateway
Expander" on page 86
Lifting system components
Exercise care when lifting system components. If necessary, get assistance to
lift a component or install components in a rack. Table 11 on page 82 lists the
CS 1000E system components provided by Nortel and the weight of each
component. Consult the manufacturer’s documentation for the weight of
other components installed during the CS 1000E system installation.
IMPORTANT!
Ensure that the unit’s power cord is appropriate for the area’s electrical
service. Do not modify or use the supplied AC power cord if it is not the
correct type.
Table 11
Weight of CS 1000E system components (Part 1 of 2)
Component Lbs Kg
ISP1100 Signaling Server 23 10.5
Media Gateway without cards
with 4 cards 26
30
12
13.5