Page 292 of 466 Installing and cross-connecting a trunk card
NN43041-310 Standard 01.11 October 2008
• NTRB21 TMDI 1.5 Mbit DTI/PRI
• NT6D70 SILC
• NT6D71 UILC
Note: Now NT6D70 SILC and NT6D71 UILC Digital trunk cards can
be installed in slots 7 to 10 in a Media Gateway Expander.
For additional information about installing Digital trunk cards, refer to the
following documents:
• ISDN Primary Rate Interface: Installation and Configuration
(NN43001-301)
• ISDN Basic Rate Interface: Installation and Configuration
(NN43001-318)
• ISDN Primary Rate Interface: Maintenance (NN43001-717)
• ISDN Basic Rate Interface: Maintenance (NN43001-718)
Connecting a trunk
Follow Procedure 66 to connect a trunk.
Procedure 66
Connecting a trunk
1 From the assignment record, determine the location of the trunk
connection and its associated Terminal Number (TN) at the
cross-connect terminal.
2 With cross-connect wire, connect the trunk to the TN.
Make sure that the wiring is not reversed and that it is on the correct
terminals.
• Table 24 on page 293 to Table 26 on page 296 list the connections
for trunks.
• For European trunk connections, see Table 27 on page 298 to
Table 35 on page 307.
• For UK trunk connections, see Table 36 on page 309 to Table 42 on
page 316.