Nortel Networks 1000E Telephone User Manual


 
Page 292 of 466 Installing and cross-connecting a trunk card
NN43041-310 Standard 01.11 October 2008
NTRB21 TMDI 1.5 Mbit DTI/PRI
NT6D70 SILC
NT6D71 UILC
Note: Now NT6D70 SILC and NT6D71 UILC Digital trunk cards can
be installed in slots 7 to 10 in a Media Gateway Expander.
For additional information about installing Digital trunk cards, refer to the
following documents:
ISDN Primary Rate Interface: Installation and Configuration
(NN43001-301)
ISDN Basic Rate Interface: Installation and Configuration
(NN43001-318)
ISDN Primary Rate Interface: Maintenance (NN43001-717)
ISDN Basic Rate Interface: Maintenance (NN43001-718)
Connecting a trunk
Follow Procedure 66 to connect a trunk.
Procedure 66
Connecting a trunk
1 From the assignment record, determine the location of the trunk
connection and its associated Terminal Number (TN) at the
cross-connect terminal.
2 With cross-connect wire, connect the trunk to the TN.
Make sure that the wiring is not reversed and that it is on the correct
terminals.
Table 24 on page 293 to Table 26 on page 296 list the connections
for trunks.
For European trunk connections, see Table 27 on page 298 to
Table 35 on page 307.
For UK trunk connections, see Table 36 on page 309 to Table 42 on
page 316.