Nortel Networks 1000E Telephone User Manual


 
Configuring an IP telephony node Page 375 of 466
Communication Server 1000E Installation and Commissioning
In Element Manager:
1 Click Edit on the Node Configuration web page (see Figure 160 on
page 369).
2 Click Add beside the Signaling Server row.
3 Enter the Follower Signaling Server data to an IP telephony node. Include
the ELAN MAC address (used to answer BootP requests).
4 Click Save and Transfer to save the changes and the Leader Signaling
Server then obtains a copy of the node files.
5 Click OK to save the node configuration to the CS 1000E and transfer the
configuration to all elements.
When the file transfer is complete, the Transfer/ Status web page
appears.
The Leader Signaling Server responds to the Follower Signaling Server's
BootP request.
The Follower Signaling Server initializes its network interfaces.
The Follower Signaling Server attempts to FTP the BOOTP.TAB file from
the node master (Leader Signaling Server).
Note: Since the Follower cannot obtain the system login and password,
the FTP fails (for first-time Follower Signaling Server installation only). It
does not have the current CONFIG.INI file that contains the CS 1000E IP
address. Subsequent FTPs succeed.
6 Transfer the node files again, so that the Follower Signaling Server
obtains a copy of CONFIG.INI.
7 Reboot the Follower Signaling Server so that all its applications can start
based on the new CONFIG.INI file.
The Signaling Server uses BootP to obtain its network data, and it then
FTPs the BOOTP.TAB file from the node master (Leader Signaling
Server).
End of Procedure
Performing a datadump
Follow Procedure 88 to perform a datadump using Element Manager. This
procedure is an alternative to using CLI to perform a datadump. The