Nortel Networks 1000E Telephone User Manual


 
System components Page 75 of 466
Communication Server 1000E Installation and Commissioning
19-inch rack
All CS 1000E system components are mounted in a customer-supplied
19-inch rack. Ground the rack and equipment to the NTDU6201 Ground Bar.
System cables
Table 9 on page 76 lists the cables required with the CS 1000E system.
The base marketing package NTHU53AA provides an NTRC17 crossover
cable to connect the LAN2 ports of the two core CP PM Call Servers. It also
contains two MRV Terminal Server cables (NTDU6302) to connect from
COM port 1 of both core CP PM Call Servers to the MRV Terminal Server.
Note: Order the proper power cord for your region.
Power Power cord connector is located on the left-hand
corner on the unit’s backplane.
Power supplies are factory installed and not
customer replaceable.
Unit is AC powered (120 V AV @ 1.58 amps).
Cooling Forced air cooling with side-to-side air flow.
The fans run at a single speed.
Ensure that equipment ventilation openings are
not blocked.
Card slots None
Connectors Twenty console ports for modular RJ-45
connectors
One RJ-45 (10BaseT) network interface
Table 8
MRV IR-8020M Terminal Server profile (Part 2 of 2)
Property Description