Nortel Networks 1000E Telephone User Manual


 
Page 106 of 466 Installing and connecting CS 1000E hardware
NN43041-310 Standard 01.11 October 2008
5 The existing 3-port SDI cable (NTBK48AA) is reused. It connects to the
SDI port on the Chassis.
This chassis, the main chassis in the system, will now become known as
IPMG 00.
End of Procedure
Installing the CP PM card
The following procedure describes how to install the CP PM card in a
Chassis.
Note: Ensure that all DIP switches are set correctly. DIP switches
determine whether the CP PM boots from a hard drive or compact flash.
Procedure 13
Installing the CP PM card
1 Ensure that the security dongle (the one that comes as part of the
software kit) is inserted on the CP PM call processor.
2 Slide the CP PM call processor into Slot 1 (or higher)
of the Chassis.
3 Lock the card into the faceplate latches.
4 Attach the SDI cable. The 50-pin Amphinol connects to the back of the
CP PM call server.