Installing Line cards and cross-connecting telephones Page 385 of 466
Communication Server 1000E Installation and Commissioning
Procedure 90
Connecting a telephone without a PFTU
1 Locate the telephone terminations on the cross-connect terminal.
2 Connect one end of the cross-connect wire to the leads of the telephone.
3 Locate the Line card terminations on the cross-connect terminal.
4 Connect the other end of the cross-connect wire to the assigned TN
terminal block.
5 Activate the telephone.
End of Procedure
Connecting an off-premise telephone
Connect off-premise analog (500/2500-type) telephones through an NT1R20
Off-premise Line card or NTAK92AA Off-Premise Protection Module. Each
NTAK92AA module can connect up to four analog (500/2500-type)
telephones and can interface with the NT8D09 Message Waiting Line card.
DANGER OF ELECTRIC SHOCK
The message-waiting Line card produces -150 volts,
which is considered hazardous on off-premise
telephones. Make sure that the -150 volts are disabled
on off-premise telephones.
The voltage is disabled when the telephone’s Class of
Service (CLS) is Message Waiting Lamp Denied (LPD)
and Message Waiting Denied (MWD) in LD 10.
Refer to the Software Input/Output: Administration
(NN43001-611) for information about LD 10.
Do not assign a Class of Service of LPA or MWA to an
off-premise telephone.