Installing a Signaling Server Page 185 of 466
Communication Server 1000E Installation and Commissioning
Procedure 40
Connecting a CP PM Signaling Server to the ELAN and TLAN subnets of
a CS 1000M system
1 Insert the end of an RJ-45 CAT5 Ethernet cable (not supplied) into the
ELAN network interface port (ELAN port) on the back of the CS 1000M
UEM. (You installed this ELAN port at the back of the UEM when you
installed the Signaling Server in the UEM.)
2 Insert the other end of the RJ-45 CAT5 Ethernet cable into an Ethernet
port on the ELAN Ethernet switch.
3 Insert the end of another RJ-45 CAT5 Ethernet cable (not supplied) into
the TLAN network interface port (TLAN port) on the back of the CS 1000M
UEM. (You installed this TLAN port at the back of the UEM when you
installed the Signaling Server in the UEM).
4 Insert the other end of the RJ-45 CAT5 Ethernet cable into an Ethernet
port on the TLAN Ethernet switch.
End of Procedure
Verify or change the baud rate
To verify or change the baud rate on a Nortel CP PM Signaling Server, see
Signaling Server: Installation and Commissioning (NN43001-312).
Connecting an IBM X306m Signaling Server
In geographic regions that are susceptible to electrical storms, Nortel
recommends that you plug the IBM X306m Signaling Server into an AC
surge suppressor.
Figure 59 shows the rear view of the IBM X306m Signaling Server.