Nortel Networks 1000E Telephone User Manual


 
Connecting an MRV LX8020S-102AC-R Terminal Server Page 269 of 466
Communication Server 1000E Installation and Commissioning
Procedure 59
Connecting a Terminal Server to the system
1 Connect the above mentioned MRV serial cable from the Terminal Server
Diag port at the front of the Terminal Server to the PC COM port.
2 Start the MRV HyperTerminal application. In Windows:
Start > Programs > Accessories > Communication >
HyperTerminal.exe
3 Configure HyperTerminal to communicate with the Terminal Server’s
management port:
a. Set baud rate to 9600.
b. Set data bits to 8.
c. Set parity to none.
d. Set stop bit to 1.
e. Set flow control to “None”.
f. Set Terminal Emulation to VT100.
g. Press <CR> until you receive a log-in prompt.
4 Log in to the Terminal Server. Enter:
Log in: InReach <Enter>
Password access
5 To log into Superuser mode:
InReach: 0 >enable <enter>
6 Enter the default password. Enter:
8 CTS 8 RTS
9 N/C
Table 21
Customer made cable pin out (same as NTDU6302)
Pins on DB9 Female Pins on RJ-45 Male (MRV Terminal Server)