The MGC Shells can be accessed using the following commands:
<CTRL>O<CTRL>A<CTRL>M, (provide OAM username and
password to access OAM shell)
<CTRL>L<CTRL>D<CTRL>B, (provide LDB username and
password to access LDB)
1 Enter network IP information at the MGC setup menu:
Please define the data networking parameters for this
MG 1000E now.
Hostname: MGC_N313 (optional)
ELAN IP: 0.0.0.0 192.168.3.33
ELAN subnet mask: 0.0.0.0 255.255.255.0
ELAN gateway IP: 192.168.3.1
TLAN IP: 0.0.0.0 192.168.19.33
TLAN subnet mask: 0.0.0.0 255.255.255.0
TLAN gateway IP : 192.168.19.1
Primary CS Hostname: CS1000E_N313 (optional)
Primary CS IP: 192.168.3.32
Leading Secondary CS Hostname:<enter>
Leading Secondary CS IP: 0.0.0.0
Secondary CS Hostname: <enter>
Secondary CS IP: 0.0.0.0