Nortel Networks 1000E Telephone User Manual


 
System components Page 57 of 466
Communication Server 1000E Installation and Commissioning
Figure 7
Connectors at the back of the ISP1100 Signaling Server
CP PM Signaling Server
The CP PM Signaling Server is in the form of a circuit card and comes in two
distinct models, NTDW61 and NTDW66. The NTDW61 model is designed
for use in a CS 1000E system and the NTDW66 model is designed for use in
a CS 1000M system.
Installation in a CS 1000E system
The NTDW61 model of the CP PM Signaling Server circuit card can be
inserted into any slot of an IPMG (MG 1000E or MG 1000B) or 11C cabinet
in a CS 1000E system, except slot 0. Slot 0 is reserved for an SSC or an MGC.
IMPORTANT!
There are several switches on CP PM circuit cards. All switch settings
must be factory defaults except for the switch labelled “S5”. Switch S5
must be set to position 2 to support the internal hard drive used on the
CP PM Signaling Server circuit cards only.
not used
TLAN (P2)
not used
ELAN (P1)
Maintenance/
Universal AC
power cord
connector
not used
Admin port