Installing a Signaling Server Page 183 of 466
Communication Server 1000E Installation and Commissioning
5 Set the COM port on the maintenance terminal as follows:
• Terminal type: VT100
• Speed: 9 600
• Data bits: 8
• Parity: none
• Stop bits: 1
• Flow control: none
Note: The CP PM Signaling Server is shipped with the Admin Serial port
set to 9600 Bit/s. Other available speeds are 19 200, 38 400, and 115 200
Bits. You can change the port speed using the maintenance terminal. To
verify or change the baud rate on a Nortel CP PM Signaling Server, see
Signaling Server: Installation and Commissioning (NN43001-312).
6 Configure the Signaling Server maintenance terminal. Refer to Signaling
Server: Installation and Commissioning (NN43001-312).
End of Procedure
Complete Procedure 39 to connect a Nortel CP PM Signaling Server (model
NTDW61BAE5) to the ELAN and TLAN subnets of a CS 1000E system.
Procedure 39
Connecting a CP PM Signaling Server to the ELAN and TLAN subnets of
a CS 1000E system
1 Connect the Signaling Server to the ELAN subnet.
• if the Call Server is not connected to the Media Gateway Controller
(MGC) CE port
— Insert the end of one of the 25-cm RJ-45 CAT5 Ethernet cables
shipped with the server (NTDU0606E6) into the ELAN network
interface port (ELAN port) on the faceplate of the server
— insert the other end of the 25-cm RJ-45 CAT5 Ethernet cable
into the MGC ELAN Ethernet port
• if the Call Server is connected to the CE port