Page 46 of 466 System components
NN43041-310 Standard 01.11 October 2008
For CS 1000 Release 5.0, the CP PM call server processor sits in one of the
slots in the MG1000E chassis.
The CP PM Call Server processor connects to the MG 1000E Media Gateway
Controllers via Ethernet and therefore does not require backplane
connectivity (other than power and slot ID). The following rules apply to the
preferential placement of the CP PM call server in the MG 1000E:
• The CP PM call server processor must not be installed in slot 0 of any
MG 1000E. This slot is reserved for the MG 1000E shelf controller card
(the MGC or the SSC).
• To allow for ease of cabling, the CP PM call server processor can be
installed in slot 1 next to the MGC or the SSC. The CP PM signaling
server can be placed in slot 2.
• If utilizing the Campus Redundancy call server redundancy option, place
the two CP PM call servers in separate MG 1000E cabinets to allow for
increased survivability.
Figure 3 on page 47 shows a CS 1000E CP PM Call Server system overview.