Nortel Networks 1000E Telephone User Manual


 
Page 204 of 466 Installing a Signaling Server
NN43041-310 Standard 01.11 October 2008
Figure 76
Signaling Server role selection
10 Configure the Signaling Server as Leader or Follower. See Figure 76 on
page 204.
If there is already a Leader Signaling Server in the IP Telephony
node, enter b at the prompt to set this Signaling Server as Follower.
The Follower Signaling Server configuration screen appears
(Figure 77 on page 205). Go to step 10 on page 224.
Please select the role of this Signaling Server.
If this Signaling Server will be a Leader then its data networking
and IP Telephony parameters must be entered now. (This will pre-
configure the IP Telephony node files.)
If this Signaling Server will be a Follower then its data networking
and IP Telephony parameters must be configured through Element
Manager later.
Please enter:
<CR> -> <a> - Set this Signaling Server as a Leader.
<b> - Set this Signaling Server as a Follower.
<q> - Quit.
Enter Choice>
=====================================================================
CS 1000 Signaling Server Software Install Tool (sse-x.xx.xx)
Note: This step will over-write all existing configuration parameters
on this Signaling Server.