A SERVICE OF

logo

Installing and configuring the Signaling Server software Page 193 of 488
Communication Server 1000E Installation and Configuration
Figure 73
IP Telephony parameter configuration
The system echoes the ELAN network interface MAC address.
For future reference, the ELAN MAC address is:
“00:02:b3:c5:5l:c6”.
This address is on the face of the Signaling Server, on the right side when
the bezel door is open.
Note: The ELAN network interface MAC address must be configured in
the Element Manager node configuration web page.
16 To complete the installation, the Installation Status Summary screen
appears as shown in Figure 74 on page 194.
CS 1000 Signaling Server Software Install Tool (sse-x.xx.xx)
=====================================================================
You have entered the following parameters for this Leader
Signaling Server:
Node ID : 276
Hostname : SS_Node276_Ldr
ELAN IP : 192.168.20.100
ELAN subnet mask: 255.255.255.0
ELAN gateway IP : 192.168.10.1
TLAN IP : 192.168.20.20
TLAN subnet mask: 255.255.255.0
TLAN gateway IP : 192.168.20.1
Node IP : 192.168.20.100
Call Server IP : 192.168.10.10
NRS configuration: Alternate GK + SIP
Primary NRS IP : 192.168.20.10
Alternate NRS IP : 192.168.20.24
Please enter:
<CR> -> <y> - Yes, these parameters are correct.
<n> - No, these parameters are not correct.
Enter Choice>