Page 160 of 466 Configuring the CS 1000E CP PM Call Server
NN43041-310 Standard 01.11 October 2008
TTY 13: DSBL DES: ether 2
TTY 14: DSBL DES: ether 3
3 Enter the command:
****
4 Perform an EDD to save your changes.
End of Procedure
Configuring Virtual Tone and Conference Circuits
Virtual Tone and Conference Circuits must be defined for use by each
MG 1000E. Use LD 17 to add MGTDS and MG Conference loops. The
Virtual Tone and Conference Circuits in the same MG 1000E must occupy
contiguous double loops. For easy management, Nortel recommends to start
the MGTDS and MG Conference loops from a loop number high enough (for
example, 60) to leave enough superloop number for all MG 1000E
superloops.
LD 17 – Add Virtual Tone and Conference loops.
Prompt Response Comment
REQ CHG Change existing data
TYPE CEQU Common Equipment
... ...
MGTDS X (x=superloop number)
IPMG a b (a=loop of MG, b=shelf of MG)
MGCONF X (x=superloop number)
IPMG a b (a=loop of MG, b=shelf of MG)