A SERVICE OF

logo

Installing and configuring the Signaling Server software Page 197 of 488
Communication Server 1000E Installation and Configuration
Verifying a successful configuration
To ensure that the Signaling Server Ethernet connections (for the ELAN and
TLAN subnets) are configured correctly, perform a ping test to one or more
of the other devices connected to the network, particularly the Call Server.
Procedure 46
Verifying the Signaling Server Ethernet connection
1 Log in to the Signaling Server, using Procedure 45 on page 196.
2 Ping the IP address of the Signaling Server. Enter the command:
ping x.x.x.x
Where x.x.x.x is the Signaling Server ELAN network interface IP
address.
3 Ping the IP address of the Call Server. Enter the command:
ping x.x.x.x,3
Where x.x.x.x is the Call Server ELAN network interface IP address.
4 If desired, repeat step 3 for other devices connected to the network.
End of Procedure
Testing the Leader Signaling Server
Configure two IP Phones to register to the Signaling Server on its temporary
node. These IP Phones must be provisioned on the Call Server.