Panasonic MINAS A5 Two-Way Radio User Manual


 
2-6
Power Supply
Remarks
100V type
: Single phase, 100V
+10%
to 120V
+10%
50/60Hz
(A to C-frame)
–15%
–15%
200V type
: Single/3-phase, 200V
+10%
to 240V
+10%
50/60Hz
(A to D-frame)
–15%
–15%
200V type
: 3-phase, 200V
+10%
to 230V
+10%
50/60Hz
(E to H-frame)
–15%
–15%
400V type
: Main power supply 3-phase, 380V
+10%
to 480V
+10%
50/60Hz
(D to H-frame)
–15%
–15%
: Control power supply DC 24V ± 15%
(1) This product is designed to be used in over-voltage category (installation category) III
of EN 61800-5-1:2007.
(2) Use an insulated power supply of DC12 to 24V which has CE marking or complies
with EN60950.
Use sheathed (jacketed) cable, twisted cable or closely bundled cable for power cable.
3RZHUFDEOHDQGVLJQDOZLUHVPXVWEHVXIÀFLHQWO\LVRODWHGIURPHDFKRWKHU
Twisted
Servo driver
L1C
L2C
Closely bundled cable
United
Servo driver
L2
L3
L1
Circuit Breaker
Install a circuit breaker which complies with IEC Standards and UL recognized (Listed
and
PDUNHGEHWZHHQSRZHUVXSSO\DQGQRLVHÀOWHU
The short-circuit protection circuit on the product is not for protection of branch circuit.
The branch circuit should be protected in accordance with NEC and the applicable local
regulations in your area.
2
Preparation
1.
Conformance to international standards
&RPSRVLWLRQRI3HULSKHUDO(TXLSPHQWV
Note
For driver and applicable peripheral equipments, refer to P.2-10 "Driver and List of Applicable
Peripheral Equipments".