Panasonic MINAS A5 Two-Way Radio User Manual


 
Protective
function
Error code No.
Causes Measures
Main Sub

1. When in Trouble
Protective function (Detail of error code)
*
CL
assignment
error
33 6
Counter clear function is assigned to a
signal number other than SI7.
Allocate correct function to each connector
pin.
*
INH
assignment
error
7
Command pulse inhibit input function is
assigned to a signal number other than
6,
Software
limit
protection
34 0
When a position command within the
VSHFLÀHGLQSXWUDQJHLVJLYHQWKHPRWRU
operates outside its working range
VSHFLÀHGLQ3U
1) Gain is not appropriate.
2) Pr5.14 setup value is low.
1) Check the gain (balance between position
loop gain and speed loop gain) and inertia
ratio.
2) Increase the setup value of Pr5.14. Or,
6HW3UWRWRGLVDEOHWKHSURWHFWLYH
function.
*
EEPROM
parameter
error
protection
36 0
Data in parameter storage area has been
damaged when reading the data from
EEPROM at power-on.
6HWXSDOOSDUDPHWHUVDJDLQ
,IWKHHUURUSHUVLVWVUHSODFHWKHGULYHULW
may be a failure.) Return the product to the
dealer or manufacturer.
1
2
*
EEPROM
check code
error
protection
37 0
'DWDIRUZULWLQJFRQÀUPDWLRQWR((3520
has been damaged when reading the
data from EEPROM at power-on.
Replace the driver. (it may be a failure).
Return the product to a dealer or
manufacturer.
1
2
*
Over-travel
inhibit
input
protection
38 0
:LWK3URYHUWUDYHOLQKLELWLQSXW
VHWXS ERWKSRVLWLYHDQGQHJDWLYH
over-travel inhibit inputs (POT/NOT)
have been ON.
:LWK3U SRVLWLYHRUQHJDWLYH
over-travel inhibit input has turned ON.
Check that there are not any errors in
switches, wires or power supply which are
connected to positive direction/ negative
direction over-travel inhibit input. Check that
the rising time of the control power supply
(DC12 to 24V) is not slow.
Analog
input 1 (AI1)
excess
protection
39 0
+LJKHUYROWDJHKDVEHHQDSSOLHGWRWKH
analog input 1 than the value that has
been set by Pr4.24.
6HWXS3UFRUUHFWO\&KHFNWKH
FRQQHFWLQJFRQGLWLRQRIWKHFRQQHFWRU;
6HWXS3UWRDQGLQYDOLGDWHWKH
protective function.
Analog
input 2 (AI2)
excess
protection
1
+LJKHUYROWDJHKDVEHHQDSSOLHGWRWKH
analog input 2 than the value that has
been set by Pr4.27.
6HWXS3UFRUUHFWO\&KHFNWKH
FRQQHFWLQJFRQGLWLRQRIWKHFRQQHFWRU;
6HWXS3UWRDQGLQYDOLGDWHWKH
protective function.
Analog
input 3 (AI3)
excess
protection
2
+LJKHUYROWDJHKDVEHHQDSSOLHGWRWKH
analog input 3 than the value that has
EHHQVHWE\3U
6HWXS3UFRUUHFWO\&KHFNWKH
FRQQHFWLQJFRQGLWLRQRIWKHFRQQHFWRU;
6HWXS3UWRDQGLQYDOLGDWHWKH
protective function.
Note
 2QO\IRUSRVLWLRQFRQWUROW\SHLVQRWSURYLGHGZLWKDQDORJLQSXW