15. How to Use the Front Panel
Monitor Mode (EXECUTION display)
(7) Display of Error Factor and Reference of History
<List of error code No.>
Error code
Protective function
Attribute
Main Sub History
Can be
cleared
Immediate
stop
11 0 Control power supply under- voltage protection
12 0 Over-voltage protection
13
0 Main power supply under-voltage protection (between P to N)
1 Main power supply under-voltage protection (AC interception detection)
14
0 Over-current protection
1 IPM error protection
15 0 Over-heat protection
16 0 Over-load protection
*1
18
0 Over-regeneration load protection
1 Over-regeneration Tr error protection
21
0 Encoder communication disconnect error protection
1 Encoder communication error protection
23 0 Encoder communication data error protection
24
0 Position deviation excess protection
1 Velocity deviation excess protection
25 0 Hybrid deviation excess error protection
26
0 Over-speed protection
1 2nd over-speed protection
27
0 Command pulse input frequency error protection
2 Command pulse multiplier error protection
28 0 Limit of pulse replay error protection
29 0 'HYLDWLRQFRXQWHURYHUÁRZSURWHFWLRQ
30 0 Safety detection
33
0 IF overlaps allocation error 1 protection
1 IF overlaps allocation error 2 protection
2 IF input function number error 1 protection
3 IF input function number error 2 protection
4 IF output function number error 1 protection
5 IF output function number error 2 protection
6 &/ÀWWLQJHUURUSURWHFWLRQ
7 ,1+ÀWWLQJHUURUSURWHFWLRQ
........Present error
........History 0 (latest error)
........History 13 (oldest error)
Error code No. ( appears if no error occurs)
<RXFDQUHIHUWKHODVW
error factors (including
present one)
Press to select
WKHIDFWRUWREHUHIHUUHG