(8) Alarm Display
alarm
No.
Alarm Content
Latched
time
*1
A0 Overload protection Load factor is 85% or more the protection level.
WRVRU
A1
Over-regeneration
alarm
Regenerative load factor is 85% or more the
protection level.
VRU
A2 Battery alarm Battery voltage is 3.2 V or lower.
)L[HGDW
A3 Fan alarm Fan has stopped for 1 sec.
WRVRU
A4
Encoder communication
alarm
The number of successive encoder communication
HUURUVH[FHHGVWKHVSHFLÀHGYDOXH
WRVRU
A5 Encoder overheat alarm The encoder detects overheat alarm.
WRVRU
A6
Oscillation detection
alarm
Oscillation or vibration is detected.
WRVRU
A7 Lifetime detection alarm Life expectancy of capacitor or fan is short.
)L[HGDW
A8
External scale error
alarm
The external scale detects the alarm.
WRVRU
A9
External scale
communication alarm
The number of successive external scale
FRPPXQLFDWLRQHUURUVH[FHHGVWKHVSHFLÀHGYDOXH
WRVRU
*1 Alarms can be cleared by using the alarm clear. Because the all existing alarms are kept cleared while the alarm
FOHDULQSXW$&/5LVNHSW21EHVXUHWRWXUQLW2))GXULQJQRUPDORSHUDWLRQ(LWKHUVRUFDQEHVHOHFWHG
by using user parameter.
([FHSWLRQ%DWWHU\DODUPLVÀ[HGDWEHFDXVHLWLVODWFKHGE\WKHHQFRGHU
%HFDXVHWKHHQGRIOLIHDODUPPHDQVWKDWWKHOLIHH[SHFWDQF\FDQQRWEHH[WHQGHGWKHDODUPLVVHWDW
......No alarm occurred
......High priority alarm
Alarm number
7RGLVSOD\WKHDODUPRFFXUUHQFHFRQGLWLRQSUHVVRUEXWWRQ
15. How to Use the Front Panel
Monitor Mode (EXECUTION display)