2-114
(5) Initialization of parameter
Initialize the parameter.
Initialization of
parameter completes
Error occurs
(Minor error occurs)
Initialization of parameter
Initialization
finishes
3UHVVWRFDOOIRU
EXECUTION display.
(SET button)
SELECTION display
EXECUTION display
“ ” increases while keep
pressing (for approx. 5sec)
as the left fig. shows.
.HHSSUHVVLQJXQWLOWKHGLVSOD\FKDQJHVWR
when you execute Initialization of parameter.
Caution
Parameter cannot be initialized when one of the following error occurs: Err11.0 “Under
voltage protection of control power supply”, EEPROM related errors (Err36.0, Err36.1,
Err36.2, Err37.0, Err37.1 and Err37.2) - initialization will result in “Error” display.
15. How to Use the Front Panel
Auxiliary Function Mode (EXECUTION display)
Note
$IWHULQLWLDOL]DWLRQRISDUDPHWHUÀQLVKHVUHWXUQWR6(/(&7,21GLVSOD\UHIHUULQJWRVWUXFWXUH
of each mode (P.2-88).