Unit Load Calculation Worksheet
9. Try to exchange modules between carriers to reduce the unit loads for
slots five and six through 27. (Remember that the 100D, 400, 400
GS/LS/TTR, 800 GS/LS-lD, 800, and 800 GS/LS modules have unit loads
of 0.0, ) Repeat Steps 1 through 8 to recalculate unit loads for new
configuration.
■
If the exchange reduces the unit load for slots five and six through
27 or less, auxiliary power is sufficient.
■
If the exchange does not reduce the unit loads for slots 5 and 6
through 27, install wall power units for the appropriate number of
telephones to reduce the unit load to 27.
NOTE:
Empty slots are not permitted between modules.
Maintenance and Troubleshooting C-9