AT&T 3.0 Telephone User Manual


 
Error Logs
Table 2-2
Continued
Error
Codes Description
Action
0012
INVALID RESET FLAG:
Troubleshoot the processor.
Processor problem.
0013
DUART STREAMING INT:
Troubleshoot the processor.
Processor problem.
0014 PROCESSOR ERR INTERRUPT:
Troubleshoot the processor.
Processor problem.
0015
MODULE MISMATCH:
Change system programming to reflect
Physical and logical type mismatch. the proper module or install the proper
Module inserted into wrong slot.
module.
0016
POWER UP COLD START:
If problem persists, troubleshoot the
A module dual port RAM failure was
module for the slot, indicated.
detected.
System programming is okay.
0C01
NO I-VMS PORT IN SERV:
No action required.
This error indicates that the VMS
machine may be down.
0C02
DID INTERDIGIT TIMEOUT:
No action required. If problem persists,
May be noisy line or central office troubleshoot the DID line and inform the
problem. central office if necessary.
1CO1
POOL M-BUSY EXCEEDS 50%:
Troubleshoot trunk.
More than half the trunks in the pool are
busy.
1C02 FW UPGRADE ATTEMPT
If
FW UPGRADE ATTEMPT
is logged and FW
UPGRADE COMPLETE
is not, the firmware
upgrade should be retried. The circuit
module should be considered unreliable
until a successful upgrade is performed.
Continued on next page
2-8 Error Logs, Access Logs, and System Inventory