Module Problems
If the test fails, find the error message in Table 4-6 and proceed as indicated.
Table 4-6. Internal Loopback Test Errors
Error Messages
Corrective Action
Slot is not busied-out
Exit the test, busy-out the slot, and try again.
Slot empty or not valid
Exit the test and try again; be sure to type the correct
slot number. Do not indicate an empty slot or the
processor (00).
FMWR not in Standby Node
Exit the test and try again; if this error persists, record
the errors on the repair tag and replace the module
being tested.
Test running too long
Exit the test and try again; if this error persists, record
the errors on the repair tag and replace the module
being tested.
Not in TEST/STANDBY mode
Exit the test and try again; if this error persists, record
the errors on the repair tag and replace the module
being tested.
Any errors on the CSU-lpbk Failed Check the cable between the 100D module and the
screen
CSU; then retest. If the problem persists, check the
CSU settings.
Exit the test and try again; if this error persists, record
the errors on the repair tag and replace the module
being tested.
Any other error
Record the errors on the repair tag and replace the
module; if in doubt, escalate to your technical support
organization.