AT&T 3.0 Telephone User Manual


 
Error Logs
Table 2-2
Continued
Error
Codes Description
Action
6COA
DS1 SLIP ALARM:
Troubleshoot the T1 trunk. If problem
Slip count reached 88.
persists, escalate to your technical
support organization.
Maintenance
Slot
Error Events
Current hr
6C0B
DS1 HARDWARE INOPERATIVE:
If problem persists, escalate to your
DS1 hardware is not operating
technical support organization.
properly. If this is the only 100D (DS1)
module, or if this is the module
designated to have the active clock,
its TDM bus clock generator was not
activated.
7001
PRI SVC AUDIT TIMEOUT:
Troubleshoot the PRI trunk and report to
service provider; otherwise, no action
required. If problem persists, contact
your technical support organization.
7002
PRI SVC STATE INCONSIST:
Troubleshoot the PRI trunk and report to
service provider; otherwise, no action
required. If problem persists, contact
your technical support organization.
7003
PRI D-CHNL INOPERATIVE:
Troubleshoot the PRI trunk and report to
service provider; otherwise, no action
required. If problem persists, contact
your technical support organization.
7004
PRI B-CHNL RELEASED:
Troubleshoot the PRI trunk and report to
service provider; otherwise, no action
required. If problem persists, contact
your technical support organization.
Continued on next page
Error Logs, Access Logs, and System Inventory 2-11