Error Logs
Table 2-2. Error Codes
Error
Codes Description
Action
000l
TIMEOUT COLD START:
No action required; however, if problem
System programming is okay.
persists, troubleshoot the processor.
0002
POWER UP WARM START:
No action required; however, if problem
System programming is okay.
persists, troubleshoot the processor.
0003
SOFTWARE COLD START:
If problem persists, troubleshoot the
System programming is okay.
processor.
0004
SOFTWARE WARM START:
If problem persists, troubleshoot the
System programming is okay.
processor.
O006
INCOMPLETE COLD START:
If problem persists, troubleshoot the
System was cold-started while a
processor.
restart was in progress.
0007
SANITY TIMEOUT RESET:
Troubleshoot module and or processor.
Faulty software, module, carrier, or
processor sanity timer.
0008
MAX RESET COUNT EXCEEDED:
If problem persists, troubleshoot the
System was cold-started (System
processor.
Reset) because too many warm starts
occurred.
System programming is okay.
Continued on next page
2-6 Error Logs, Access Logs, and System Inventory