Lucent Technologies 107970212 Answering Machine User Manual


 
Installation
7.
8.
After approximately 10 seconds when the tests are completed, the yellow
Test LED goes off. When this occurs, check the red Status LED:
If the red Status LED is not lit, the module passed the tests. Continue
with Step 8.
If the red Status LED is lit, power down the control unit, re-install the
Mailbox Expansion Card if it was installed in Step 4, then power up the
control unit again. If the red Status LED comes on again, call for
support as indicated on the inside front cover.
After the module passes the self-diagnostic tests, the extensions
associated with the voice messaging system module go off-hook. Two
outside lines show red steady on system phones with those lines for
about one minute. When the lines become idle, the voice messaging
system is ready to receive calls.
2-6