Lucent Technologies 107970212 Answering Machine User Manual


 
Specifications
Environmental
Requirements—
Control Unit
Mount on a wall at least 2 feet (0.6 meters) from the floor
(wall mounting required)
Locate within 5 feet (1.5 meters) of the network interface
jacks and a properly grounded electrical outlet not
controlled by switch, using supplied 7-foot (2.1 meter)
cords
Mount the Expansion Carrier at least 6” (15.2 cm) and not
more than 24” (61 cm) away from the Primary Carrier
Operating temperature 32° to +104°F (0° to +40°C), not in
direct sunlight
Humidity 15%-90%, noncondensing
For proper ventilation and easy replacement of modules,
provide at least 6” (15.2cm) clearance at the top and
sides and 2 feet (0.6 meters) at the front and bottom of
the control unit
Locate in an area free of excess moisture, corrosive
gases, dust and chemicals
Electrical
U.S. and Canada: 90–130 VAC, 50–60 Hz, 3-prong outlet
Requirements
separate ground, separately fused at 15 Amps: Other
countries: 180–264 VAC, 50–60 Hz, fused at 10 Amps
Outlet must not be controlled by an on/off switch
Grounding to comply with Underwriters Laboratories (UL)
1459:
1.
2.
3.
An insulated grounding conductor that is not smaller in
size and equivalent in insulation material and thickness
to the grounded and ungrounded branch circuit
supply conductors, except that it is green with or
without one or more yellow stripes, is to be installed as
part of the circuit that supplies the product or system.
The grounding conductor mentioned in item A is to be
connected to ground at service equipment.
The attachment-plug receptacles in the vicinity of the
product or system are all to be of a grounding type,
and the grounding conductors serving these
receptacles are to be connected to earth ground at
the service equipment.
Safety
U.S.: Meets UL 1459 Issue 2
Requirements
Canada: Meets CSA C22.2, 225
A-3