Nortel Networks BCM1000 Telephone User Manual


 
18 BCM1000 version 3.0 addendum
DSM16+ and DSM 32+ double density switch settings (upgraded system)
The following table shows the switch settings for DSM-plus modules deployed as double density on a system that
has been upgraded from 2.5 to 3.0.
Table 3 DSM 16/DSM 16+ and DSM 32/DSM32+ single density switch settings for 2.5 systems upgraded to 3.0
Select
DS30
bus
Enter these switch settings
**To assign
these DNs to
DSM16 or
DSM 16+
To assign these DNs to DSM 32 or
DSM 32+
To assign these DNs to
Companion*****
1 2 3 456
02
on on on on on on
221-236 221-252 (DS30 02 and 03)
N/A
03
on on on on on off
237-252 237-268 (DS30 03 and 04)
04
on on on on off on
253-268 253-284) (DS30 04 and 05)
05
on on on on off off
269-284 269-300 (DS30 05 and 06)
06
on on on off on on
285-300 285-316 (DS30 06 and 07) 565-580**** (PDD only)
***07
on on on off on off
301-316 N/A 581-596**** (PDD only)
**The extensions listed are based on a three-digit DN with a Start DN of 221. If your system has longer DNs or a different Start DN,
enter the range in the blank column.
***If your system is configured with a 3/5 DS30 split, you cannot use DS30 07 for the DSM 16 module. You cannot configure the
DSM32 module for DS30 06 because the second set of DNs cannot be accessed.
****If you need more DNs for Companion sets, use the range that starts at 597 (ISDN or DECT) and change the
DN type to NA Portable.
*****If you system is set to Full Double Density (FDD), Companion telephones are not supported.
Note: DSM modules deployed with 2.5 systems are all single density and cannot be set to double density.
The DSM 16+ and DSM32+ modules can be set to either density.
Table 4 DSM 16+ and DSM32+ double density switch settings for 2.5 systems upgraded to 3.0
Select
DS30 bus
Enter these switch settings
**To assign these DNs to DSM 16+:
(A= DSM1, B=DSM2)
To assign these DNs to DSM 32+
(connectors: A=top,
B = bottom)
12 3456
02
off on on on on on A
221-236 A 377-392
off on off on on on B
377-392 B 221-236
03
off on on on on off A
237-252 A 393-408
off on off on on off B
393-408 B 237-252
04
off on on on off on A
253-268 A 409-424
off on off on off on B
409-424 B 253-268
05
off on on on off off A
269-284 A 425-440
off on off on off off B
425-440 B 269-284
06
off on on off on on A
285-300 A 441-456****
off on off off on on B
441-456**** B 285-300
***07
off on on off on off A
301-316 A 457-472*****
off on off off on off B
457-472***** B 301-316*****
**The extensions listed are based on a three-digit DN with a Start DN of 221. If your system has longer DNs or a different Start DN,
enter the range in the blank column.
***If your system is configured with a 3/5 split, you cannot use DS30 07 for the DSM 16 module.
****Available only on systems set to FDD. Modules cannot be set to double density on systems set to PDD. Refer to the previous chart
for the switch settings for single density and PDD.
*****Available only on systems set to FDD, with a 2/6 DS30 split. Modules cannot be set to double density on systems set to PDD. Refer
to the previous chart for the switch settings for single density and PDD.