Nortel Networks BCM1000 Telephone User Manual


 
214 Chapter 15 Troubleshooting
P0993298 02
3 To set the parameters for the System Status Sanity check, click the LED Settings tab.
The LED Settings record appears.
Figure 88 System Status Monitor LED Settings record
Table 44 lists the values on the LED Settings screen.
Emergency telephone does not function
If the emergency telephone is connected to the system, use the following procedure:
1 Check the power LED on the ASM 8 to check that the ASM 8 is receiving power.
2 Check that the emergency telephone has dial tone.
3 Check the external line and emergency telephone connections.
4 To avoid damage to the emergency telephone, connect the telephone directly to the external
line and check for dial tone.
5 Replace the MSC.
Table 44 LED Display screen settings
Attribute Values Description
Version Read only. The current version of the LED monitoring application.
Reset Yes, No, N/A Use Yes to allow the system status monitor board to reset the
computing platform in the event that the sanity check fails the
user set parameters.
Sanity Time 60-255
Default: 240
The time in seconds between sanity checks.
Timeouts 0-254
Default: 10
The number of sanity checks that must fail before the system
status monitor sends a reset signal to the computing platform.