Performing a loopback test
Follow the steps in Procedure 10 to perform a loopback test on the M2250
attendant console.
Procedure 10
Performing a loopback test on the
M2250 attendant console
1 Make a loopback connector. Prepare a blank 25-way RS-232 plug by
internally connecting pins 2 and 3 together with strapping wire.
2 Press the Shift key to access Level 1 mode.
3 Press the F4 (function) key to access the Diagnostics menu on the LCD
screen.
4 Plug the loopback connector into the Data Port RS-232 jack in the back
of the console.
5 Select the Data Port option from the Diagnostics menu by dialing 3. The
LCD screen displays OK when the test is successfully completed.
If there is a hardware fault on the M2250, A0H is displayed.
If the blank RS-232 connector is not plugged into the data port correctly
(as described in Step 4), the display reads 90H or A0H.
6 Press the asterisk (*) key to repeat the test.
7 To exit the test mode press the octothorpe (#). to return to the main
Diagnostics menu.
8 Press the octothorpe (#) to return to normal operating mode.
9 Remove the loopback connector from the Data Port RS-232 jack.
End of Procedure