Page 116 of 504 M2016S Secure Set
553-3001-367 Standard 3.00 August 2005
Figure 23
M2016S cross-connections.
The M2016S set has a self-testing capability. Follow the steps in
Procedure 25 to perform the self-test after installing an M2016S set, or any of
the hardware options, to ensure proper operation.
Procedure 25
M2016S self-test
1 Unplug the line cord from the telephone.
2 While holding down the RLS key, plug in the line cord to the telephone.
Let go of the RLS key.
Unit 0
Unit 1
Unit 6
Unit 7
T0
R0
T1
R1
T6
R6
T7
R7
26
1
28
3
38
13
40
16
W-BL
BL-W
W-G
G-W
BK-G
G-BK
BK-S
S-BK
T0
R0
T1
R1
T6
R6
T7
R7
G
R
W
B
Line cord
to telephone
For Power
Supply leads
to telephone
to telephone
to telephone
PE shelf
Line
Pack
Pack
connector
Part of
25 pair cable
Shelf
connector
Part of 25
pair cable
Cross connect
block
Telephone
connecting
block, or connector
553-AAA0587