Page 404 of 504 Appendix C: Meridian Modular Telephones add-on modules installation
553-3001-367 Standard 3.00 August 2005
Reattaching the Base
13 Make sure that all ribbon cables are lying flat and not caught on any posts
on the telephone cover or base.
14 Replace the base.
15 Insert all screws and tighten them.
16 If the telephone has an MCA or MPDA, plug its cable into the jack on the
telephone base.
17 Install the footstand, and secure it with two screws.
18 Reconnect all cords, including the handset.
Note: Place the label supplied with the power supply board on the
outside of the bottom cover of the telephone. This allows proper
identification and tracking of the option level of the set.
End of Procedure
Installing displays
The following procedures cover installation of the various displays on the
various sets.
• Procedure 73: “Installing and removing the M2616/M2216ACD Display
on NTZK sets” on page 405
• Procedure 74: “Installing and removing the M2616 Display on NT2K
sets” on page 408
• Procedure 75: “Installing NT2K28AA displays on NTZK or NT2K sets”
on page 411
CAUTION
For the M2616 and M2008HF, make sure that the
microphone has not been moved from its black
rubber holder. The holder should be seated in the
main board near the ribbon cable that was just
attached.