Nortel Networks M3110 Telephone User Manual


 
Page 368 of 504 Appendix B: Meridian Modular Telephones installation
553-3001-367 Standard 3.00 August 2005
Procedure 65
Designating Meridian Modular Telephones
1 Remove the cap from each key requiring a designation.
2 Place the designation in the cap, place the cap over the corresponding
key, and gently press down. Repeat for all keys requiring designations.
3 Insert a paper clip into the hole at the left or right end of the designation
window.
4 Gently pry the window toward the center and remove, and insert the
number tag.
5 Replace the designation window.
End of Procedure
Cross-connect the telephones
Follow the steps in Procedure 66 to cross-connect the telephones. Refer to
Figure 64 on page 370 for an illustration of cross-connections.
Procedure 66
Cross-connecting the telephones
1 Locate the telephone terminations at the cross-connect terminal.
Telephone terminations are located on the vertical side of the frame when
frame-mounted blocks are used and in the blue field when wall-mounted
blocks are used.
2 Connect Z-type cross-connecting wire to the leads of the telephone. See
Table 63 on page 369 and Table 64 on page 369.
3 Locate the line circuit card (TN) terminations.
Line circuit card (TN) terminations are located on the horizontal side of the
distributing frame when frame-mounted blocks are used and in the white
field when wall-mounted blocks are used.
4 Run and connect the other end of the cross-connecting wire to the
assigned TN terminal block.
End of Procedure