Nortel Networks M3110 Telephone User Manual


 
Page 112 of 504 M2016S Secure Set
553-3001-367 Standard 3.00 August 2005
adapter (refer to Figure 21 on page 113) can provide the additional power
needed to operate the telephone and its options.
120 V transformer (AO367335 or equivalent). The following minimum
specifications must be met by this transformer:
Input voltage: 120 V AC / 60 Hz
No load output voltage: 29 V AC maximum
Voltage at rated current: 26.7 V AC minimum
Rated load current: 700 mA
240 V transformer (AO367914 or equivalent). The following minimum
specifications have to be met by this transformer:
Input voltage: 240 V AC / 50 Hz
No load output voltage: 29 V AC maximum
Voltage at rated current: 26.7 V AC minimum
Rated load current: 700 mA
Note: You cannot wall mount the telephone over the wall jack when
using a transformer, due to the size of the RJ-11 adapter. Hang it above
or to the side of the jack and run the line and power cords to it.
WARNING
Do not plug any equipment (computer, modem, LAN
card) other than the M2016S into the RJ-11 transformer
adapter, as damage to equipment may result.