Nortel Networks M3110 Telephone User Manual


 
Page 458 of 504 Appendix D: M2317 telephone
553-3001-367 Standard 3.00 August 2005
Data communication
The M2317 can be equipped with an Asynchronous Data Option which will
permit the use of either the telephone's dial pad or the feature keys to place
and terminate data calls in the asynchronous mode. The Data Option also
supports keyboard dialing from the data terminal when that terminal operates
in the asynchronous mode.
The Asynchronous Data Option is equipped with a dialing feature which
enables the user to originate data calls to local and remote Data Terminal
Equipment (DTE) directly from a data terminal keyboard or personal
computer. The dialing feature, in conjunction with the communications
firmware provided with the Data Option, supports most of the HAYES
Smartmodem dialing features. Terminal emulation packages can also be used
with the dialing feature.
Data characteristics
The M2317 Asynchronous Data Option communicates with Data Terminal
Equipment (DTE) having characteristics as follows:
Data type ASCII
Synchronization Asynchronous, Start-Stop
Number of Bits 8 bits
Parity none (unchecked)
Data rate 300, 1200, 2400, 4800,
9600, 19200 bits per second (autobaud)
Stop bits 2 bits for 110 bits per second;
1 bit for all other speeds
Transmission Full duplex