Nortel Networks M3110 Telephone User Manual


 
Page 268 of 504 M3900 Flash Download
553-3001-367 Standard 3.00 August 2005
-lwout <loadware patch number(s)>
removes one or more loadware patches from the switch
-lwstat <loadware patch number(s)>
displays status of loadware patches on switch
if no patch numbers given, displays all patches
The loadware patches must be located in the /u/loadware directory. Below is
the example of loadware patching.
pdt> lwload ger1ba50.p
Loading loadware patch from "c:/u/loadware/ger1ba50.p"
Loadware patch number is 0.
pdt> lwinst 0
The existing c:/p/sl1/psdl.rec will be deleted
Do you wish to back up this file (y/n)? [n]
Loadware "GER1BA49" will be replaced by "GER1BA50"
Do you wish to continue (y/n) [y]
Building system loadware. This will take a few minutes.
Done. Must reboot for changes to take effect.
pdt> lwstat 0
Base loadware version: 56
Number of patches installed: 1
Loadware patch number: 0
Patch file: c:/u/loadware/ger1ba50.p
Patchname: GER1 L/w
Ref. number: mplr12345
PRS number: mp12345
Engineer: DE
Created: Mon Feb 5 10:47:25 2001