Nortel Networks M3110 Telephone User Manual


 
Page 348 of 504 Appendix A: Meridian Modular Telephones
553-3001-367 Standard 3.00 August 2005
Local plug-in transformer
A single winding transformer equipped with a 10 ft. (3 m) cord of 22 AWG
two-conductor stranded and twisted wire with a modular RJ-11 duplex
adapter (refer to Figure 59 on page 349) can provide the additional power
needed to operate the telephone and its options.
Table 56
NTZK model Power requirements, Meridian Modular Telephone sets
Telephone type Loop power
Additional power
(Power Supply Board)
M2006 Basic configuration MPDA, External Alerter Interface,
MCA (optional),
M2008 Basic configuration Any option(s)
M2616 Basic configuration (with Handsfree)
and Display.
MPDA, Key Expansion Module,
External Alerter Interface, MCA
(optional)
M2216ACD-1 Basic configuration (with Display) MPDA, Key Expansion Module,
External Alerter Interface, MCA
(optional)
M2216ACD-2 N/A Any configuration
WARNING
Do not plug any equipment (computer, modem, LAN
card) other than the Meridian Modular Telephone into
the RJ-11 transformer adapter, as damage to equipment
may result.