Toshiba DK14 Answering Machine User Manual


 
System & Station
Program 15 – Ground/Loop/Tie/DID Line Options
3-44 Strata DK Programming 5/99
Program 15 – Ground/Loop/Tie/DID Line Options
Processor Type:
DK14, DK40i, All RCTUs
Program Type:
System
Initialized Default:
All LEDs are OFF
Processor Type CO Line Range Processor Type CO Line Range
DK14 001~004 RCTUBA/BB 001~048
DK40i 001~012 RCTUC/D 001~144
RCTUA 001~016 RCTUE/F 001~200
Program Code
Program LED ON LED OFF
Line
LED
01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20
0
CPC on AR VM
Calls and Voice
Calls
Detect Ignore
1
CO/DID/Tie Line
Signal
DP DTMF
2
CO/DID/Tie Dial
Pulse Rate
(Pulse per sec.)
20 PPS 10 PPS
3
AR Hold Detect Ignore
4
AR Timing Crossbar
95 msec.
ESS
(electronic)
450 msec.
5
Tandem CO Line
Connection with
Station Dropout
Enabled Not
Enabled
7
Forced Account
Code
Enabled Not
Enabled
8
Operation After CO
Line Flash
No DTMF
receiver
After Flash
DTMF
receiver
After Flash
SELECT = Program Code
Press Scroll to advance or
to go back.
To advance the CO line range, press
located beneath the LCD. Press
for a
lower range.
LED Buttons = CO line
Specify CO line by setting LEDs as defined by the
table below. When you are finished, all LEDs with
an “X” should be lit.