Toshiba DK14 Answering Machine User Manual


 
System & Station
Program 10-3 – System Assignments, Part 3 of 3
Strata DK Programming 5/99 3-37
System & Station
LEDs 13-10: SMDI Station Number Digit Length
Set LED 10-13 ON so that the hex values add up to the Voice Mail station digit length for SMDI
VM interface. (Example: For VP100 or Stratagy/Stratagy DK SMDI interface, set LEDs 10, 11,
and 12 on for 7 digits (1+2+4=7).
Do not set LED 10-13 OFF for Toshiba proprietary interface; it is no longer supported by DK
systems.
This refers to the station digit length that the SMDI voice mail system design requires. This
parameter is set for the Voice Mail system digit length; not the DK station digit length. If the voice
mail system SMDI is designed per the Bellcore Standard TR-TSY-000283, 1985 version, set this
parameter to seven-digits (LEDs 10, 11, and 12 ON which is equal to Hex 7). Current VP and
Stratagy voice mail SMDI systems are designed for this seven-digit operation.
If the voice mail system SMDI is designed per the Bellcore Standard TR-NWT-000283, 1991
version, set this parameter between 1-10 digits with LEDs 10, 11, 12, and 13. (See Program 10-3
record sheet for LED-HEX values.) Digit length setting is not necessary with Toshiba Proprietary
Interface (LED 10-13 OFF).
LED 08: Caller ID / Automatic Number ID
This option determines if Caller ID (CLID) and/or Automatic Number Identification (ANI)
telephone numbers will be sent out the system SMDI port (SMDI only not Toshiba proprietary):
Turn LED 08, 10, 11, 12, and 13 ON if received Caller ID and/or ANI numbers should be sent
out the system SMDI port.
Turn LED 08 OFF (initialized default) if received Caller ID and/or ANI numbers should not be
sent out the system SMDI port.
LED 09: SMDI Bellcore Standard Version
Toshiba Proprietary and SMDI is available with RCTUB2 or RCTUC/RCTUD2 Release 2 and
above only and is only for use with Toshiba VP systems, not with Toshiba Stratagy systems.
Bellcore released two versions of the SMDI specification. Contact your voice mail machine
vendor to determine which specification to enable with this program – TR-TSY-000283, Issue 1,
July 1985 version, or the TR-NWT-000283, Issue 2, May 1991 version. Toshiba VP and Stratagy
SMDI products currently use the 1985 version. In either case, the VM station digit length must be
set with LED 10~13 as shown above.
Also note that the 1985 and 1991 version Bellcore specifications use different space/character
parameters for some call types which means the DK will not operate properly if the correct version
is not selected. Select the 1985 version (LED 09 OFF) for Toshiba VP and Stratagy products. This
selection is not needed with Toshiba Proprietary Interface.