Program *66-3 – Channel Group/Trunk Parameters
7-24 Strata DK Programming 5/99
Program *66-3 – Channel Group/Trunk Parameters
Processor Type:
All RCTUs (Release 4.0 or higher)
Program Type:
Trunk, PRI
Initialized Default:
Blank
LEDs 03~06 specify the trunk types shown in the following table.
Program *66-3 Overview
This program assigns special call treatment and defines the ISDN service. Call treatment includes
whether or not operator calls are allowed, if carrier access is allowed, etc. The ISDN service is
similar to trunk type, such as POTS, FX, Tie, outWATS and inWATS.
Program *66-4 Call-by-Call Network ID
See “Programs *66-2 and *66-4 – Call-by-Call Trunk Group Codes and Network ID” on Page
7-22. Use the record sheet for Program *66-2.
LEDs POTS FX
Tie
(senderized)
Tie
(cutthrough)
OutWATS
(IntraLATA)
OutWATS
(InterLATA)
InWATS
03 ON ON ON
04 ON ON ON ON
05 ON
06 ON ON
LEDs Setting
Trunk Groups
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
01
ON: Operator Calls Allowed/
OFF: Not allowed
02
ON: Carrier Access allowed
OFF: Not allowed
03
Trunk Group Type (see above table).
04
Trunk Group Type (see above table).
05
Trunk Group Type (see above table).
06
Trunk Group Type (see above table).
07~10
Not Used
11
ON: Called Party Number Type Unknown
OFF: Standard Called Party Number Type
12
ON: DK sends Ringback Tone to Network
OFF: No RBT to Network.
(Default is ON.)
13
ON: DMS CO switches only
OFF: Belcore (Default is OFF.)
DATA = Light LEDS to assign
features. See tables below.
SEL = 3
Enter the ISDN Trunk
Group Number (01~16)