ISDN
Program *61 – Analog Trunk Services for ISDN
Strata DK Programming 5/99 7-15
ISDN
Program *61 – Analog Trunk Services for ISDN
Processor Type:
DK40i, All RCTUs (Release 4.0 or higher)
Program Type:
Trunk, PRI and BRI
Initialized Default:
see below
Program *61 Overview
When analog CO lines use ISDN facilities, each analog CO Line needs to be assigned the type of
service expected to be used when originating calls. The choices are Speech or 3.1 kHz (used for
modem and fax connections). Set the transmission level for outgoing and incoming paths for calls.
The default is set for -6 dB.
Data Pad Level (db) Data Pad Level (db)
00 4-12
1-3 5-15
2-6 6-18
3-9 7+3
Trunk
Number
Bearer Service
*61-1
Outgoing Pad
Level *61-2
Incoming Pad
Level *61-3
Enter the trunk number(s) being defined.
To add a range, enter XXX
XXX (low
trunk number
high trunk number).
DATA = For *61-2 and *61-3, enter Pad
Level (default is 2). See legend below.
SEL = Type of Service (1~3)
1 - Bearer Service
2 - Outgoing Call Pad Level
3 - Incoming Call Pad Level
Enter the Bearer Service:
0 = 3.1 kHz Audio
1 = Speech (default)